(주)선일인아인스투루먼트

  • Home
  • Raman
    • BioProcessing
    • Micro Analysis >
      • RXN1 microprobe
      • Raman WorkStation
    • Macro / PAT >
      • PhAT
      • Raman WorkStation
    • Reaction Monitoring >
      • RXN1
      • RXN2 multi
      • RXN2 Hybrid
      • RXN3 Pilot
      • RXN4
    • HandHeld >
      • Serstech 100
      • NanoRam
      • TacticID
    • Portable >
      • i-Raman Plus
      • i-Raman Pro
      • i-Raman Pro-ST
      • i-Raman EX
      • GemRam
    • Gas Analysis >
      • RXN4 Gas-Phase Analyzer
  • FTIR
    • ThreatID - Portable FTIR
  • Peptide 합성
    • 펩타이드 자동합성기 >
      • PurePep Chorus
      • Symphony X
      • PurePep Sonata +
      • Symphony / Quartet
      • Prelude X
      • Tribute UV-IR
      • SonataXT
      • PS3
    • 아미노산
    • 레진(Resin)
    • Coupling 시약
  • Sampling Tools
    • Micro Sampling Tools >
      • EZ-SliceIR
      • Micro Vice
      • MicroVice SliceIR
      • EZ-PICK III
      • Diamond-EX-Press-II
      • Mini Plane Sectioning Knife
      • Micro TouchPick Pen
      • Microscope Slices
      • Sample Holders
    • FTIR accesories >
      • SurveyIR - Micro Analysis
      • MicromATR - ATR
      • MicromATR Vision - ATR Imaging
      • Micro Contact Monitor
      • Si-CheckIR
      • LC-CollectIR
    • Spectral Analysis >
      • Spectral Database
      • Spectral Analysis Software
  • 회사소개
    • 새소식
    • 협력회사 >
      • 해외 >
        • Kaiser Optical Systems Inc.
        • Smiths Detection
        • BWTEK
        • Agilent(A2)
        • STJapan
        • PIKE
        • Specac
        • ICL
        • Gemini
        • LabCognition
        • Protein Technoloiges
      • 국내
    • contact us
  • .
  • Home
  • Raman
    • BioProcessing
    • Micro Analysis >
      • RXN1 microprobe
      • Raman WorkStation
    • Macro / PAT >
      • PhAT
      • Raman WorkStation
    • Reaction Monitoring >
      • RXN1
      • RXN2 multi
      • RXN2 Hybrid
      • RXN3 Pilot
      • RXN4
    • HandHeld >
      • Serstech 100
      • NanoRam
      • TacticID
    • Portable >
      • i-Raman Plus
      • i-Raman Pro
      • i-Raman Pro-ST
      • i-Raman EX
      • GemRam
    • Gas Analysis >
      • RXN4 Gas-Phase Analyzer
  • FTIR
    • ThreatID - Portable FTIR
  • Peptide 합성
    • 펩타이드 자동합성기 >
      • PurePep Chorus
      • Symphony X
      • PurePep Sonata +
      • Symphony / Quartet
      • Prelude X
      • Tribute UV-IR
      • SonataXT
      • PS3
    • 아미노산
    • 레진(Resin)
    • Coupling 시약
  • Sampling Tools
    • Micro Sampling Tools >
      • EZ-SliceIR
      • Micro Vice
      • MicroVice SliceIR
      • EZ-PICK III
      • Diamond-EX-Press-II
      • Mini Plane Sectioning Knife
      • Micro TouchPick Pen
      • Microscope Slices
      • Sample Holders
    • FTIR accesories >
      • SurveyIR - Micro Analysis
      • MicromATR - ATR
      • MicromATR Vision - ATR Imaging
      • Micro Contact Monitor
      • Si-CheckIR
      • LC-CollectIR
    • Spectral Analysis >
      • Spectral Database
      • Spectral Analysis Software
  • 회사소개
    • 새소식
    • 협력회사 >
      • 해외 >
        • Kaiser Optical Systems Inc.
        • Smiths Detection
        • BWTEK
        • Agilent(A2)
        • STJapan
        • PIKE
        • Specac
        • ICL
        • Gemini
        • LabCognition
        • Protein Technoloiges
      • 국내
    • contact us
  • .
Home > Sampling Tools > ATR > μContact MonitorⅡ

μContact MonitorⅡ

그림
ATR 압력 모니터링 장비

By attaching this device to the MicromATR device, it becomes a device for simply measuring the pressure when the pressurizing pin presses against the measurement sample.
In ATR measurement, peak intensity varies depending on the degree of adhesion (pressurizing force) to ATR crystal and measurement sample generally, so even in the same sample measurement, if the degree of pressurization is different by the measurer, red The peak intensity of the external absorption spectrum also changes.
Since this device can display numerical values of pressure values, measurement with constant pressure becomes possible, and by using a function to set the upper limit value of pressure force, it is caused by applying excessive pressure It was developed and manufactured for the purpose of avoiding damage to the ATR crystal that would be formed.
Specification
• The maximum load : 100 Ns (about 10 kg) 
• Power supply voltage:   AC/DC adaptor   Input AC100-240 [V] 50/60Hz 0.3A, output:DC5V 2A 
• Display style : (Newton [N] / percent [%]) 
• Function : it is an automatic zero point adjustment function at the time of a pressurization high-limit-setting function,
  a setting upper limit attainment buzzer, a manual zero reset function, and the power supply ON. 
• Dimensions of indicator: W88xD33xH146 
• Display weight : 230g 


Powered by Create your own unique website with customizable templates.